logo
Guangzhou Sande Electric Co.,Ltd.
E-mail Sales01@sande-elec.com Telefone: 86--18620505228
Lar > produtos > Peças sobressalentes de automação >
3RT2027-1AP00 Siemens Power Contactor 3RT20271AP00 New Factory Sealed
  • 3RT2027-1AP00 Siemens Power Contactor 3RT20271AP00  New Factory Sealed
  • 3RT2027-1AP00 Siemens Power Contactor 3RT20271AP00  New Factory Sealed
  • 3RT2027-1AP00 Siemens Power Contactor 3RT20271AP00  New Factory Sealed
  • 3RT2027-1AP00 Siemens Power Contactor 3RT20271AP00  New Factory Sealed
  • 3RT2027-1AP00 Siemens Power Contactor 3RT20271AP00  New Factory Sealed

3RT2027-1AP00 Siemens Power Contactor 3RT20271AP00 New Factory Sealed

Lugar de origem Alemanha
Marca Siemens
Certificação CE RoHS
Número do modelo 3RT2027-1AP00
Detalhes do produto
Marca:
Siemens
Modelo:
3RT2027-1AP00
Tipo de produto:
Contactor de alimentação
Série:
SÍRIO 3RT
Configuração do Pólo:
3 pólos
Corrente operacional nominal:
32 A
Potência motora classificada:
15 kW a 400 V
Tipo de terminal:
Terminal de parafuso
Garantia:
um ano
Termos de pagamento e envio
Quantidade de ordem mínima
1
Preço
USD 40-90 / piece
Detalhes da embalagem
embalagem original
Tempo de entrega
2 dias
Termos de pagamento
L/C,D/A,D/P,T/T,Western Union
Habilidade da fonte
100 unidades por dia
Descrição do produto
Siemens 3RT2027-1AP00 Power Contactor
Product Overview

The Siemens 3RT2027-1AP00 is a 3-pole power contactor from the SIRIUS 3RT2 series, designed for switching AC induction motors in industrial machinery, production lines, and building services installations. With a 32A rating and 15kW capacity at 400V, it handles motor switching requirements for mid-sized applications including conveyor drives, pump motors, compressors, and HVAC systems.

Part Number: 3RT2027-1AP00

Manufacturer: Siemens AG

Product Family: SIRIUS 3RT2

Type: 3-Pole Power Contactor (AC Motor Switching)

Technical Specifications
Parameter Value
Part Number 3RT2027-1AP00
Manufacturer Siemens
Product Series SIRIUS 3RT2
Utilisation Category AC-3e / AC-3
Main Contact Configuration 3 NO (3-pole)
Rated Current (AC-3, 400V) 32 A
Motor Rating 15 kW @ 400V / 7.5 kW @ 230V
AC-1 Current (non-inductive) Up to 50 A
Coil Voltage 230V AC, 50 Hz
Integrated Auxiliary 1 NO + 1 NC
Size S0
Connection Screw terminals
Insulation Voltage (Ui) 690 V
Impulse Withstand Voltage 6 kV
Degree of Protection IP20
Ambient Temperature −25°C to +60°C (with derating above +40°C)
Mechanical Life Up to 10 million operations
Certifications IEC, UL, CSA, CE, CCC, RoHS
Weight Approx. 0.46 kg
Dimensions (H×W×D) 85 × 45 × 97 mm
AC-3 Utilisation Category

The AC-3 (and enhanced AC-3e) utilisation category defines the contactor's designed switching duty for squirrel-cage induction motor starting and stopping. This includes closing under full locked-rotor current and opening at running speed - the most common industrial motor switching duty.

The 32A AC-3 rating indicates the contactor can switch motors drawing up to 32A at running speed while handling the associated inrush current during startup. For less demanding applications like resistive loads, the AC-1 rating allows handling up to 50A.

SIRIUS System Integration

The 3RT2 contactor features standardized mechanical dimensions and interfaces that align with the SIRIUS modular system. This enables direct integration with compatible components:

  • Overload relays from the 3RU2 range clip directly onto the contactor
  • 3RA2 reversing combinations use linked contactors with factory-tested modules
  • PMC function modules and auxiliary switch blocks attach to defined interface positions

This modular approach reduces design complexity, wiring time, and ensures predictable space requirements in control panels.

Control Circuit & Coil Operation

The 230V AC coil energizes when voltage is applied between A1 and A2 terminals. The coil draws higher inrush current during initial energization, settling to lower holding current once seated. Standard practice includes using surge suppressors across A1-A2 terminals when driven by PLC outputs to protect against inductive kickback voltage spikes.

Frequently Asked Questions
Q: The contactor chatters during operation. What should be checked?

Chattering typically indicates a coil voltage problem. Measure voltage directly at the A1-A2 terminals during operation to ensure it remains above the minimum holding threshold. Check for voltage drops from long cable runs, undersized conductors, or loose connections.

Q: The motor runs but the overload relay trips immediately. Is the contactor at fault?

The contactor itself doesn't affect overload relay tripping. Verify the motor's starting current profile matches the relay's settings and ensure the relay is set for the motor's actual full-load current, not the contactor's rated current.

Q: Is this a direct replacement for the 3RT1027-1AP00?

Yes, the 3RT2027-1AP00 is the direct successor to the 3RT1027-1AP00. Mechanical dimensions, mounting interfaces, electrical ratings, and SIRIUS accessory compatibility are maintained across the transition.

Q: How many start/stop cycles can this contactor handle?

Mechanical life reaches approximately 10 million cycles. Electrical life under AC-3 duty typically ranges from 1-3 million operations at rated current, depending on switching frequency and current levels.

Q: Does the contactor require derating at 50°C ambient temperature?

Yes, derating applies above 40°C ambient. Consult the product datasheet for exact current values at 50°C. If the derated current remains above the motor's full-load current, the contactor can be used; otherwise, specify the next size up.